202405-28Submersible Vertical Turbine Pump Maintenance (Part A)
Why is maintenance for submersible vertical turbine pump required? Regardless of the application or operating conditions, a clear routine maintenance schedule can extend the life of your pump. Good maintenance can make equipment last longer, requ...
-
202405-24Deep Well Vertical Turbine Pumps
-
202405-21Reverse Running Speed of Deep Well Vertical Turbine Pump
Reverse running speed refers to the speed (also called return speed, reverse speed) of adeep well vertical turbine pumpwhen fluid flows through the pump in the reverse direction under a certain head (that is, the total head difference between the pump out...
-
202405-16SPLIT CAASE PUMP PROCESSING
-
202405-14About the Minimum Flow Valve of the Multistage Vertical Turbine Pump
The minimum flow valve, also known as the automatic recirculation valve, is a pump protection valve installed at the outlet of the multistage vertical turbine pump to prevent damage caused by overheating, severe noise, instability and cavitation when the ...
-
202405-10SPLIT CASE PUMP SHAFT PROCESSING
-
202405-08The Relationship Between Discharge Pressure and Head of Deep Well Vertical Turbine Pump
1. Pump Discharge Pressure The discharge pressure ofa deep well vertical turbine pumprefers to the total pressure energy (unit: MPa) of the liquid being sent after passing through the water pump. It is an important indicator of whether the pump can co...
-
202404-30Happy Labor Day 2024
We'll have the International Labor's Day from May 1 to 4th.May your Labor Day be as extraordinary as you are!Happy Labor Day!
-
202404-29Introduction to Mechanical Seal Failure of Deep Well Vertical Turbine Pump
In many pump systems, the mechanical seal is often the first component to fail. They are also the most common cause ofdeep well vertical turbine pumpdowntime and carry more repair costs than any other part of the pump. Usually, the seal itself is not the ...
-
202404-28FM FIRE PUMPS
-
202404-24SPLIT CASE PUMP IMPELLER PROCESSING
-
202404-22How to Calculate the Shaft Power Required for a Deep Well Vertical Turbine Pump
1. Pump shaft power calculation formula Flow rate × head × 9.81 × medium specific gravity ÷ 3600 ÷ pump efficiency Flow unit: cubic/hour, Lift unit: meters P=2.73HQ/η, Among them, H is the head in m, Q is the flow rate in m3/h, and η i...